This guide is for the person holding the tools. It gathers the fixing, waste and water details from our specification sheets in one place. Always work from the specification sheet for the exact unit, which is on its product page and on the Specifiers page.
1. How each type fixes
| Unit | Fixing | Weight |
|---|---|---|
| Dual Level Wall Mounted | Wall-hung or floor-mounted. Hangers supplied. | 47 kg gross |
| Dual Level Floor Mounted and Dual Level 2.0 | Floor mounted. | 50 kg |
| Foot wash troughs | Floor-mounted or recessed. Between walls or freestanding. | See specification sheet |
| All-in-one and front trough units | Rear wall fixing with keyhole slots. Stools bolt to the floor with fixing tabs. | See specification sheet |
| Anti-ligature units | Floor mounted, with a bolt-on stool option. | See specification sheet |
| Wheelchair Unit | Wall keyhole slots and floor fixing holes. | See specification sheet |
| Flow | Freestanding solid surface, assembled from base, side and back panels. | 120 kg gross |
| Pod | Freestanding solid surface. | 214 kg net, 300 kg gross |
| Hayat | Marble sink and stool in a solid surface frame. | 435 kg net, 589 kg gross |
For the Flow, Pod and Hayat, check the floor loading and measure the doors, lifts and corridors on the way in.
2. Waste and drainage
- Dual Level 2.0 and Paradise: water inlet and waste through the floor, with an S-trap.
- All-in-one and front trough units: 45 mm waste outlet, 1½ inch BSP. The all-in-one has a removable front panel for pipework access.
- Anti-ligature units: 45 mm waste outlet, with an access panel for maintenance.
- Foot wash troughs: the waste can be on the left or the right, through a 101 mm outside-diameter tube dropper.
- Recessed troughs: the recess cut-out is 440 mm wide and 90 mm deep, by the length of the trough.
Units drain through their own waste. In a busy room a floor gully is still worth having, because some water always reaches the floor. See wudu area design.
3. Taps and water pressure
| Tap | Supply | Pressure |
|---|---|---|
| Timed Flow Bib Tap | Single hot or cold supply, ½ inch BSP inlet. Runs about 12 seconds per press. | 0.2 to 5 bar working, 10 bar maximum static |
| Sensor Tap | Cold or premixed supply. Mains or battery powered. | 0.5 to 9 bar |
| Pull-Out Mixer Tap | Hot and cold, ½ inch BSP with flexible connectors. Fits the Paradise and Flex. | 1 to 3 bar. High-pressure systems only, not gravity-fed |
For warm water from a single-supply tap, the water must be blended before it reaches the tap. Fit the thermostatic mixing and backflow protection that the water fittings regulations and the building's own policy require. That is the installer's responsibility.
4. Before the day
- Download the specification sheet for the exact unit and finish.
- Confirm the wall or floor can take the fixing and the weight.
- Mark the supply and waste positions, and whether they come through the wall or the floor.
- Check the water pressure against the tap.
- Check the route in for size and weight.
- Agree the floor finish and any falls with the designer before the unit goes down.
5. After fitting
- Run every tap and check each waste for leaks before any panel goes back on.
- Set the flow on timed taps. The Timed Flow Bib Tap has five settings and leaves the factory at the middle one.
- Fit signage so the unit is not mistaken for an ordinary sink.
- Show the cleaning team the unit, including any hinged grate on a trough.
If you would rather not fit it yourself, our own team installs from £99, and our support line is open by phone, email and WhatsApp. Call 0333 577 0513.
Questions
Can any plumber install a wudu station?
Most plumbers can. Every WuduWash product arrives with pipework, wastage and taps, and each has a specification sheet. Our own team can also install, from £99.
What waste size does a wudu unit need?
The stainless steel all-in-one, front trough and anti-ligature units have a 45 mm waste outlet. Foot wash troughs drain through a 101 mm outside-diameter tube dropper. Check the specification sheet for the exact unit.
Can a foot wash trough be recessed into the floor?
Yes. WuduWash foot wash troughs can be floor-mounted or recessed. The recess cut-out is 440 mm wide and 90 mm deep, by the length of the trough.
What water pressure do wudu taps need?
The Timed Flow Bib Tap works from 0.2 to 5 bar and the Sensor Tap from 0.5 to 9 bar. The Pull-Out Mixer Tap needs 1 to 3 bar and is not suitable for gravity-fed systems.
More guides
- Wudu area design: how to plan an ablution area
- Multi-faith room washing facilities: what to provide
- Wudu at work: an employer's guide to wudu facilities
- Wudu facilities in schools and universities: a guide for estates teams
- Wudu facilities in hospitals: a guide for estates and chaplaincy teams
- Anti-ligature wudu units: a guide for mental health and secure settings
- How many wudu stations does a mosque need?
- Wudu basin buying guide: ceramic, acrylic, solid surface or stainless steel
- Wudu sink with foot wash for the home: sizes, plumbing and price
- What is an ablution unit?
- Ablution areas for UAE and Gulf projects: a specifier's guide